2023.10.12
Points of this article
・"Power Device Solution Circuits" for power devices are divided into three categories--AD-DC PFCs, DC-AC inverters, and DC-DC converters; various simulation circuits are available.
・In this section, inverter circuits among the Power Device Solution Circuits are used to explain basic methods for adjusting different parameters and related know-how.
In succession to the previous “Optimization of PFC Circuits“, this article initiates a discussion of “Optimization of Inverter Circuits” using the ROHM Solution Simulator.
The ROHM Solution Simulator, which is a web-based simulation tool that can be used simply by registering at MyROHM, offers numerous Solution Circuits. “Power Device Solution Circuits” for power devices are classified into three categories, which are AD-DC PFCs, DC-AC inverters, and DC-DC Converters; various solution circuits are provided.
In this section, basic methods for adjusting different parameters and related know-how are introduced using inverter circuits among the Power Device Solution Circuits. Examples are presented in which simulations are used to pursue optimization with respect to three important matters requiring study in inverter circuit design: the influence of trr, selection of optimal devices based on losses, and features of half-bridge and full-bridge designs.
The “User Guide: Inverters” document on which this article is based can be downloaded from the following link:
We begin by presenting a list of the Power Device Solution Circuits for inverter circuits that are currently available. Starting with general single-phase half-bridge and full-bridge circuits, in addition to 3-phase inverters and 3-level inverters, there are also circuits available for specific applications such as IH inverters and motor drives.
Category | Control No | Circuit Specifications |
---|---|---|
IH Inverter | B-1 | IH Half-Bridge Inverter Po=10kW |
B-2 | IH Full-Bridge Inverter Po=20kW | |
Half-Bridge Inverter | B-3 | Half-Bridge Inverter Vo=200V Io=100A |
Full-Bridge Inverter | B-4 | Full-Bridge Inverter Vo=200V Io=100A |
1-Phase 3-Wire Inverter | B-5 | 1-Phase 3-Wire Inverter Vo=100/200V Po=20kW |
3-Phase Inverter | B-6 | 3-Phase 3-Wire Inverter Vo=200V Po=5kW |
B-7 | 3-Phase 4-Wire Inverter Vo=115/200V Po=20kW | |
Motor Drive | B-8 | Motor Drive 2-Phase-Modulation Po=10kW |
B-9 | Motor Drive 3-Phase-Modulation Po=10kW | |
B-10 | Motor Drive Step-Modulation Po=5kW | |
3-level Inverter | B-11 | 3-level Inverter type-T Vo=200V Io=50A |
B-12 | 3-level Inverter type-I Vo=200V Io=50A |
Downloadable materials, including lecture materials from ROHM-sponsored seminars and a selection guide for DC-DC converters, are now available.
Downloadable materials, including lecture materials from ROHM-sponsored seminars and a selection guide for DC-DC converters, are now available.