This article explains the operation screens of the RAGU® software.
●Main GUI
The main screen has the following 4 areas, indicated by the red rectangles (01) to (04) in the screen image.
(01) ON Switch: Enables access to RAGU
(02) DUT Control Settings: Input control signals of DUT (motor driver LSI)
(03) Graph/Plot Area: Graphs and measured values
(04) Oscilloscope Settings: Performs settings for the oscilloscope
Below are described the settings for each of the 3 areas other than the ON switch.
●DUT Control Settings
Aside from the switch ON display, the DUT control area has 4 settings: “Level”, “Computation”, “Clock output”, and “Pin voltage levels”. The table below shows settings for each of these.
(01) Operating Mode | Switch that enables access to RAGU | |
---|---|---|
(02) Levels | (a) Voltage level |
|
(b) Frequency level |
|
|
(03) Computation |
|
|
(04) CLK Output |
|
|
(05) Pin voltage level |
|
●Graph/Plot Area and Oscilloscope Settings
The graph/plot area and the oscilloscope settings area are related, and so these are explained together. Broadly stated, there are settings for the “graph/plot area”, for the “channel settings”, and for “sampling evaluation”. For details of each of these, please refer to the table below the graphic image.
(01) Graph/plot area | (a) Time-delta measurement |
|
---|---|---|
(b) Time-value display |
|
|
(C) Horizontal scroll |
|
|
(02) Channel settings | (a) On/Off |
|
(b) Source |
|
|
(c) Output |
|
|
(d) Value/Div |
|
|
(e) Range |
|
|
(f) Setup |
|
|
(g) Sec/Div |
|
|
(h) Sampling rate |
|
|
(03) Sampling evaluation | (a) Trigger |
|
(b) Channel |
|
|
(c) Current |
|
|
(d) Voltage |
|
|
(e) Run/Stop |
|
|
(f) Save |
|
|
Note: Only one slider is active at any time. The active slider will depend on the input type (voltage/current) of the currently selected channel. |
●Dynamic Window (Refer to “④ Explanation of RAG U V1.0 Functions”)
The dynamic window is a “DUT control setting”. It is selected by choosing “View → Dynamic Window Menu Item”.
●Temperature Monitor (Refer to “④ Explanation of RAG U V1.0 Functions”)
The Temperature Monitor is also a “DUT control setting”. It is selected by choosing “View → Tj Monitor Menu Item”.
●Calibrate
The calibrate function is found under the Help Menu. Ensure that all oscilloscope functions are turned off before calibrating the RAGU main board (RAGU-main1-EVK-001) or the RAGU option board (RAGU-op1-EVK-001). Calibrating the boards while using the oscilloscope may result in an incorrect calibration.