2018.09.06
Points of this article
・The core size, primary inductance and number of turns for a transformer T1 are calculated according to the procedure described.
・Calculations can be performed according to more or less the same approach as in “Designing Isolated Flyback Converter Circuits: Transformer Design (Calculating Numerical Values)”
In the previous section, “Transformer T1 Design ? 1”, we explained the calculation procedure ① through ③ below. As Part 2 of this discussion, we here perform the remaining calculations ④ to ⑥, to complete design of the transformer T1.
As explained in the previous section, parameters that must be derived for the transformer design are the core size, the inductance Lp, and the winding turns Np, Ns, Nd. In the previous section, we already calculated the core size and the inductance Lp.
Parameters Necessary for Transformer Design
Transformer core size | EFD30 or compatible |
---|---|
Lp (Primary winding inductance) | 1750μH |
Np (Primary winding turns) | (to be calculated in ④) |
Ns (Secondary winding turns) | (to be calculated in ⑤) |
Nd (VCC winding turns) | (to be calculated in ⑥) |
In addition, conditions imposed on the transformer T1 are an output of 24 V at 1 A, and VIN(DC) of from 300 V to 900 V.
Please consult the linked circuit diagram as necessary.
As the fourth procedure, the number of primary winding turns Np is calculated. The maximum value of the flux density B(T) for general ferrite cores is 0.4 T at 100°C, and so we set Bsat = 0.3 T.
In order to avoid magnetic saturation, the AL value-NI characteristic must be confirmed and care taken to ensure that the transformer is used in a region where saturation does not occur. For this purpose, we use an AL value-NI characteristic graph.
For example, if we try setting Np = 50 turns, then we have
and the saturation region is entered.
The number of primary winding turns is set so as to avoid the saturation region.
In the case of Np = 64 turns,
and operation is in a region without saturation. Hence we set Np = 64 turns.
Next, we calculate the secondary winding turns Ns. In “①Setting a flyback voltage VOR”, it was found that Np/Ns = 8, and so this is used here.
From the following equation, the number of VCC winding turns Nd is found. It is assumed that VCC = 24 V and Vf_vcc = 1 V.
The 24 V for VCC is the standard required voltage for the BD7682FJ-LB, which is the IC used in this design. A SiC MOSFET is being driven, and so a gate voltage (OUT pin clamp voltage) of 18 V (typ) is needed.
With this, calculation of all the required parameters is complete. We have inserted the numerical values into the table that appeared previously.
Parameters Necessary for Transformer Design
Transformer core size | EFD30 or compatible |
---|---|
Lp (Primary winding inductance) | 1750 μH |
Np (Primary winding turns) | 64 turns |
Ns (Secondary winding turns) | 8 turns |
Nd (VCC winding turns) | 8 turns |
To conclude, we present a design example for a transformer based on these parameters.
Basic studies to understand AC-DC converters and to go designing.
Basic studies to understand AC-DC converters and to go designing.